Everything about Evaporative Cooling totally explained
Evaporative cooling is a physical phenomenon in which
evaporation of a liquid, typically into surrounding air, cools an object or a liquid in contact with it.
Latent heat describes the amount of heat that's needed to evaporate the liquid; this heat comes from the liquid itself and the surrounding gas and surfaces. When considering water evaporating into air, the
wet-bulb temperature, as compared to the air's
dry-bulb temperature, is a measure of the potential for evaporative cooling. The greater the difference between the two temperatures, the greater the evaporative cooling effect. When the temperatures are the same, no net evaporation of water in air occurs, thus there's no cooling effect.
The simplest example would be perspiration, or
sweat, which the body secretes in order to cool itself. The amount of heat transfer depends on the evaporation rate, which in turn depends on the
humidity of the air and its temperature, which is why you sweat more on hot, humid days.
Another, recent application of evaporative cooling is the "self-refrigerating" beverage can.
(External Link
) A separate compartment inside the can contains a
desiccant and cooling liquid. Just before consumption, the desiccant comes into contact with the cooling liquid, inducing evaporation.
Evaporative cooling was in vogue for aircraft designs for some time in the late 1930s. In this case the system was used in order to reduce, or eliminate completely, the
radiator which would otherwise create considerable drag. In these systems the water in the engine was kept under pressure with pumps, allowing it to heat to temperatures above 100 Celsius, as the actual boiling point is a function of the pressure. The super-heated water was then sprayed though a nozzle into an open tube, where it rapidly boiled and released its heat. The tubes could be placed under the skin of the aircraft, resulting in a zero-drag cooling system.
However these systems also had serious disadvantages. Since the amount of tubing needed to cool the water was large, the cooling system covered a significant portion of the plane even though it was hidden. This led to all sorts of added complexity and the systems were always terribly unreliable. In addition this large size meant it was very easy for it to be hit by enemy fire, and practically impossible to armor. British and US attempts to use the system turned to
ethylene glycol instead. The Germans instead used streamlining and positioning of traditional radiators. Even its most ardent supporters,
Heinkel's
Günter brothers, eventually gave up on it in 1940.
Evaporative cooling was used in some automobiles, often as aftermarket accessories, until modern vapor-compression air-conditioning became widely available.
Evaporative cooling is a very common form of cooling buildings for
thermal comfort since it's relatively cheap and requires less energy than many other forms of cooling. However evaporative cooling requires an abundant water source as an evaporate, and is only efficient when the relative humidity is low, restricting its effective use to dry climates.
Evaporative coolers are colloquially referred to as
swamp coolers in the U.S. In other places they're known as desert coolers.
Evaporative cooling is commonly used in
cryogenic applications. The vapor above a reservoir of cryogenic liquid is pumped away, and the liquid continuously evaporates as long as the liquid's
vapor pressure is significant. Evaporative cooling of ordinary
helium forms a
1-K pot, which can cool to at least 1.2 K. Evaporative cooling of
helium-3 can provide temperatures below 300 mK. Each of these techniques can be used to make
cryocoolers, or as components of lower-temperature
cryostats such as
dilution refrigerators. As the temperature decreases, the vapor pressure of the liquid also falls, and cooling becomes less effective. This sets a lower limit to the temperature attainable with a given liquid.
This process has recently been observed to operate on a planetary scale on
Pluto and acts as an
Anti-Greenhouse Effect.
Evaporative cooling is also the last cooling step in order to reach the ultra-low temperatures required for
Bose-Einstein Condensation (BEC). Here, so-called
forced evaporative cooling is used to selectively remove high-energetic ("hot") atoms from an atom cloud until the remaining cloud is cooled below the BEC transition temperature. For a cloud of 1 million alkali atoms, this temperature is about 1μK.
Further Information
Get more info on 'Evaporative Cooling'.
|
External Link Exchanges
Do you know how hard it is to get a link from a large encyclopaedia? Well we're different and will prove it. To get a link from us just add the following HTML to your site on a relevant page:
<a href="http://evaporative_cooling.totallyexplained.com">Evaporative cooling Totally Explained</a>
Then simply click through this link from your web page. Our crawlers will verify your link, extract the title of your web page and instantly add a link back to it. If you like you can remove the words Totally Explained and embed the link in article text.
As long as your link remains in place, we'll keep our link to you right here. Please play fair - our crawlers are watching. Your site must be closely related to this one's topic. Any kind of spamming, dubious practises or removing the link will result in your link from us being dropped and, potentially, your whole site being banned. |